CLEANING-IN-PLACE & STERILIZATION-IN-PLACE SYSTEMS

Bram-Cor CPSG - CIP

CIP/SIP Systems in Pharmaceutical GMP Manufacturing

Cleaning the systems without disassembling

Thanks to the advent of CIP (Clean-In-Place) and SIP (Sterilization-In-Place) technologies, sealed systems such as pipes, vessels or process equipment in technical process plants can be cleaned without the need to disassemble the systems. This is a great time-saving advantage in industrial sectors where fixed and regular cleaning was required, such as pharmaceutical industry, food and beverage. 

CIP - CLEANING IN PLACE

The cleaning method allows the internal surfaces of a sealed system to be entirely cleaned without disassembly or with disassembly of a limited number of components. CIP cycles are typically automated, with defined times and parameters. The cleaning operation -with temperatures up to 100°C- is performed through a series of steps with turbulent flows: Pre-rinsing, Cleaning with lye (typically NaOH), Rinsing off the lye with water, Cleaning with acid, Rinsing off the acid with water, Final water rinsing.

SIP - STERILIZATION IN PLACE

Steam sterilization of the pharmaceutical processing plant takes place after CIP, as a further sterilization step. It is an indispensable operation in areas where germ reduction plays a prime role. SIP reduces the microbial load to a validated sterility assurance level. The system can use hot water or saturated pure steam at high temperatures (>120 °C) and about 2 bar(g), for a variable period (>60 minutes) depending on the specific application. 

Design and validation criteria

  • Cleaning effectiveness depends on four interacting factors: time, mechanical action (flow velocity or spray coverage), chemical concentration and temperature.
  • Piping: turbulent flow in the circuit [indicare la velocità minima di progetto], absence of dead legs, full drainability.
  • Vessels: spray devices whose coverage is verified in qualification [verificare il metodo].
  • Monitoring and recording of temperature, flow, conductivity and, where required, TOC of the final rinse.
  • SIP: temperature verified at the coldest point of the circuit, effective condensate drainage and steam quality (pure steam, see WFI by PSG).
  • Cleaning validation: acceptance limits, worst-case selection, rinse and swab sampling [riferimento: EU GMP Annex 15].

 

CIP Systems, with mobile or fixed units

BRAM-COR Clean-in-Place systems are designed to meet cGMPs requirements in cleaning and sterilizing practices commonly applied in pharmaceutical process lines and plants. Bram-Cor CIP/SIP stations are available as mobile and fixed units, in single-tank or multi-tank configuration. Design starts from: type and size of the equipment to be cleaned, type of water and cleaning agents, product residues to be removed, type of spray devices, washing sequence and level of automation.

Each BRAM-COR CIP/SIP equipment is designed (in single or multitank configuration) to achieve effective and easily validable cleaning systems, starting from: type and size of equipment to wash, Required type of water and chemical agent, Pharmaceutical product to remove, Cleaning nozzles type, Washing sequence, automation level.  

 

Bram-Cor Mobile CIP units Clean-In-Place Stations

Movable CIP units - The mobile systems can have easy positioning 

 

Clean-In-Place (CIP) Systems - customized fixed stations

 

You  can enlarge and/or rotate the 3D image

You  can enlarge and/or rotate the 3D image